Adams Rite 7170-510-628-00 Electric Strike
Remote electrical control of narrow stile aluminum doors (7160) or hollow metal/wood doors (7170) equipped with a mortise or cylindrical lockset with up to 3/4" [19.1 mm] latchbolt projection without deadbolt. Electrical actuation unlocks the keeper, releasing the latchbolt so the door may be opened without operating the latch itself. The electric strike must be positioned to accommodate offset mortise latches during installation. Please refer to installation instructions or contact factory for more information.
Certifications:
- UL 1034 burglary-resistant listed
- UL 294 (6th Edition) listed
Case: 1" x 3-3/8" x 1-7/8" deep [25.4 mm x 85.7 mm x 47.6 mm].
Strike Opening: Bolt retaining keeper is stainless steel. Strike location must be centered on latchbolt.
- 7160: 3/4" x 1-7/16" x 5/8" deep [19.1 mm x 36.5 mm x 15.9 mm deep].
- 7170: 5/8" x 1-7/16" x 5/8" deep[15.9 mm x 36.5 mm x 15.9 mm deep].
Strike Lip: Basic strike has lip of proper length for 1-3/4" [44.5 mm] thick door that closes flush with jamb edge. Where door thickness or jamb shape differs from this standard relationship, lip extension kits are available, specified by last dash number.
Latchbolt Projection: 3/4" [19.1 mm]
Faceplate: 1-1/4" x 4-7/8" [31.8 mm x 123.8 mm]. Available in a variety of architectural finishes.
- 7160: Flat with radius corners
- 7170: Flat with square corners
Standard Package: Individually boxed with mounting screws.
- 7160 includes mounting clips, adhesive shims to accommodate jamb or stile extrusion thickness greater or less than nominal 1/8" [3.2 mm].
- 7170 includes mounting clips and adhesive shims for use when welded tabs are omitted.
Shipping weight: 2 lbs [0.91 kg].
Voltage: Available in 12, 16, or 24 Volt AC and DC. DC continuous units are silent, AC intermittent units “buzz” on operation.
Current Draw:
- 0.33A at 12 VDC, 1.42A at 12 VAC
- 0.22A at 16 VDC, 0.63A at 16 VAC
- 0.17A at 24 VDC, 0.74A at 24 VAC
Fail Safe | Fail Secure: Field selectable at time of installation. However, AC intermittent solenoid must not be used continuously in either.