  • Clear anodized aluminum retainer with black neoprene bulb seal
  • jamb weatherstrip for sealing doors
  • UL Fire Rated for use on fire doors
  • self drilling #8 (Tek) screws supplied
  • screw holes slotted for adjustment
US$147.52

Description:

Description:

NGP 700Na Alum Neoprene Perimeter Seal One Ea 36 Two 84

  • Aluminum Alloy 6063, T5 Temper
  • Synthetic EPDM Rubber in Polypropylene Thermoplastic Matrix
  • Very Good Abrasion Resistance, Tensile Strength and Memory
  • Flame-Resistant
  • Moisture-Resistant
  • Temperature Range -81°F to 275°F
  • Good Resistance to Ozone, Sunlight and Aging
  • BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat and Cold
  • #No Break in Seal for Closer Mounting
  • Closer and/or Overhead Holder Attach to Frame Through Weatherseal Section. Install Seal First
  • Allows Mounting of Rim Exit Device Strikes Without Notching Gasketing
  • Head Section Not Drilled
  • Jamb Sections Furnished With Slotted Holes for Adjustment
  • Self Drilling #8 (Tek Type) Screws Furnished
  • Color is Black
  • Anodized Aluminum

Standards
CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.

POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.

AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.

ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G8 thru G10 of our Gasketing catalog for test result data.

SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category ‘H’; complies with IBC and NFPA 105 for use on ‘S’ labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.

ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.