NGP GAP90-36 90Min Fire Door Top Jamp GAP Solution 36 Long
POSITIVE PRESSURE – CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16".
CERTIFIED by UL to ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16".
- Requires installation of ALL components 9945, 9400, 5075
- Certified for use on doors with Rim Exit Devices, refer to Installation Instructions
- Doors with Parallel arm closers – use 9990
- An NGP Strike Shim (9275 or 9225) may also be Required for Proper Latchbolt Engagement
- Available in 36″, 48″, 84″ and 96″ lengths (order 1 piece for head and 2 pieces for jambs)